BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Session Board//Session Board//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
BEGIN:VEVENT
UID:12735-20261018T094500Z@www.hcdexpo.com
DTSTAMP:20260623T135838Z
DTSTART:20261018T094500Z
DTEND:20261018T104500Z
SUMMARY:E10 &#8211\; Evidence from the Field: POE-Informed Strategies for Hospital Expansion
DESCRIPTION:As healthcare campuses expand to meet growing community demand\, understanding how existing facilities perform in practice is essential to making informed\, future-ready design decisions. Post-occupancy evaluation (POE) provides a critical feedback loop\, allowing organizations to assess how spatial design impacts staff workflows\, safety\, environmental comfort\, and overall operational performance. This session presents findings from a comprehensive\, multi-method POE conducted at UNC Johnston Health and demonstrates how the results directly informed planning priorities for campus expansion and renovation efforts.\nThe POE evaluated five clinical departments—Labor &amp\; Delivery\, Postpartum\, ICU &amp\; PCU\, Med-Surg\, and Nursery—using staff surveys\, walkthroughs\, spatial analysis\, and open-ended feedback. Across departments\, findings revealed consistent themes related to staff work area functionality\, visibility and adjacency for patient monitoring\, adequacy of support spaces\, and the impact of storage\, equipment placement\, and circulation on workflow efficiency. While patient room size and overall unit layout were frequently cited as strengths\, staff satisfaction was negatively affected by undersized nurse stations\, limited charting privacy\, poorly located restrooms\, inadequate staff amenities\, and inconsistent zoning of clean and soiled supplies.\nDepartment-specific insights highlighted how localized design decisions can have system-wide operational consequences. In Labor &amp\; Delivery and Postpartum units\, nurse station configuration\, lighting quality\, and charting orientation influenced teamwork and patient visibility. In ICU\, PCU\, and Med-Surg units\, staff amenities\, equipment access\, pneumatic tube placement\, and lift availability affected efficiency\, safety\, and staff well-being. In the Nursery\, the square footage and outdated infrastructure constrained limited clinical functionality and emergency preparedness.\nThe presentation translates these findings into actionable design strategies\, illustrating how POE-informed recommendations—such as optimizing staff work zones\, improving storage and equipment planning\, enhancing staff amenities\, and clarifying circulation—can improve performance while supporting future growth. 
LOCATION:
END:VEVENT
END:VCALENDAR